Mesaj gönder
Ana sayfa ÜrünlerKlima santralı

Super slim Ceiling Hanging Chilled Water Air Handling Units 1500-5000m3/h

Super slim Ceiling Hanging Chilled Water Air Handling Units 1500-5000m3/h

  • Super slim Ceiling Hanging Chilled Water Air Handling Units 1500-5000m3/h
  • Super slim Ceiling Hanging Chilled Water Air Handling Units 1500-5000m3/h
Super slim Ceiling Hanging Chilled Water Air Handling Units 1500-5000m3/h
Ürün ayrıntıları:
Place of Origin: China
Marka adı: EuroKlimat
Sertifika: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKSW-D
Ödeme & teslimat koşulları:
Minimum Order Quantity: 1
Fiyat: negotiation
Packaging Details: Plywood
Delivery Time: 15 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
İletişim
Detaylı ürün tanımı
Product Name: Super-slim Air Handling Units Installation: Ceiling hang/floor installation
Cooling Capacity(kW): 6-84 Heating Capacity(kW): 11-87
Air Flow(m3/h): 1500-5000 Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa): 3.3 Coils rows: 4/6
Vurgulamak:

custom air handling units

,

chilled water air handling unit

 

 

Super-slim Compact Desgin Chilled Water Air Handling Units

 

Specifciations

 

 

Unit Model

EKSW

015D

EKSW

020D

EKSW

025D

EKSW

030D

EKSW

035D

EKSW

040D

EKSW

050D

Nominal air flow (m3/h) 1500 2000 2500 3000 3500 4000 5000
External static pressure (Pa) 70 100 100 120 120 150 150
Nominal cooling capacity (kW) Four rows of coils (in air return condition) 6 10 12 16 18 23 29
Four rows of coils (in fresh air condition)  19 27 31 40 47 57 70
Six rows of coils (in air return condition)  10 15 17 22 26 31 37
Six rows of coils (in fresh air condition) 25 34 39 49 61 70 84
Nominal heating capacity (kW) Four rows of coils (in air return condition) 11 16 19 24 28 34 42
Four rows of coils (in fresh air condition)  21 30 34 43 52 61 73
Six rows of coils (in air return condition)  15 21 23 29 36 42 50
Six rows of coils (in fresh air condition) 26 36 41 51 64 74 87
Nominal input power (W) Four rows of coils  373 614 787 797 905 1248 1533
Six rows of coils  397 653 823 845 1016 1362 1699
Nominal input current (A) Four rows of coils  1.72 2.96 3.61 3.62 4.22 5.68 6.98
Six rows of coils  1.81 3.01 3.78 3.96 5.1 6.29 7.86
Water flow (m3/h) Cooling
condition
Air return condition

1.01

(1.78)

1.77

(2.57)

2.40

(3.36)

3.13

(4.18)

3.09

(4.58)

3.91

(5.36)

5.32

(7.06)

Fresh air condition

3.26

(4.30)

4.69

(5.95)

6.07

(7.61)

7.65

(9.29)

8.21

(10.5)

9.78

(12.15)

12.89

(15.59)

Heating
condition
Air return condition

0.96

(1.27)

1.38

(1.78)

1.80

(2.28)

2.27

(2.79)

2.42

(3.14)

2.91

(3.64)

3.83

(4.69)

Fresh air condition

1.85

(2.30)

2.57

(3.14)

3.26

(3.98)

4.07

(4.84)

4.47

(5.52)

5.28

(6.36)

6.83

(8.10)

Water resistance (kPa) Cooling
condition
Air return condition 5(14) 14(27) 24(54) 14(21) 13(44) 25(45) 40(75)
Fresh air condition 39(77) 40(89) 46(96) 32(76) 36(79) 46(103) 74(113)
Heating
condition
Air return condition 4(12) 12(24) 10(24) 9(12) 11(32) 19(30) 24(32)
Fresh air condition 20(42) 26(49) 24(62) 26(56) 20(53) 31(68) 67(70)
Coil Model High-quality air conditioner copper tubes are connected to 
hyperbolic aluminum plate-fins through mechanical expanding.
Heat exchanger 12
Working pressure (MPa)  1.6
Inlet/outlet pipe connector size R1-1/2
Condensed water pipe connector size R3/4
Fan Type/material Centrifugal dual suction impeller with forward curved galvanized steel plate
Transmission mode Joint transmission
Air supply direction of the fan Downward horizontal
Motor  Power supply  220V~/50Hz
Model High precision low noise ball bearing single-phase capacitor-run motor
Degree of protection IP20
Insulation rank B
Unit noise (dB(A)) HF 44.1 50.6 55.7 52.5 53.5 53.6 57.0
MF 40.7 48.0 52.2 50.5 52.1 51.5 56.0
LF 37.7 45.1 48.4 48.5 50.2 49.5 54.9
Filter Model Primary nylon filter
Thickness (mm) 21
Box  Model The galvanized steel plate applies static spraying and the internal is 
attached with efficient insulation sound-proof PE material.
Unit Outer Dimensions Length (mm) 750 910 1070 1220 1370 1520 1850
Width (mm)  750 750 750 750 750 750 750
Height (mm)  420 420 420 420 420 420 420
Unit weight (kg) Four rows of coils  76 80 86 92 96 102 108
Six rows of coils  79 84 90 96 101 107 113

 

Note:
■ The preceding parameters apply to the standard model. EK provides customized design to meet special requirements.
■ Nominal air return cooling condition: 27°C (dry bulb)/19.5°C (wet bulb). Nominal fresh air cooling condition: 34°C (dry bulb)/28°C (wet bulb). Nominal cooling
water inlet/outlet temperature: inlet 7°C; outlet 12°C.
■ Nominal air return heating condition: 21°C (dry bulb). Nominal fresh air heating condition: 0°C (dry bulb). Nominal heating water inlet/outlet temperature: inlet
60°C; outlet 50°C.
■ The unit weight listed in the table is net weight. The operating weight increases by about 20%.
■ The noise values in the preceding table are measured at a distance of 1 m from the unit in a state certified standard semi-anechoic room according to the GBT
9068-1988 standard.
■ If the external total pressure value of the unit used in model selection is large, the air flow will be large, leading to noise and water spray. Therefore, carefully
determine the air duct resistance.
■ The power and current in the table are measured when the unit is in high rotation speed under rated air flow and air pressure.

 


Pleasant appearance: 

 

Highly intensive galvanized steel plates with orange-peel static powder spraying are used for pleasant appearance and efficient erosion prevention.

 

Low noise: 

 

Comprehensive noise reduction design is used. High-quality low-noise motors and low-rotation performing fans are selected. In addition, the fan motor incorporates overall vibration reduction design and runs at a low noise. A horizontal unit adopts flexible connection by using quality canvas, which efficiently isolates vibration from fans and reduces noises generated by air flows. With the industry-leading noise processing technology, this unit can fully meet customer requirements for low noise. The horizontal super-slim unit reduces the noise to as low as 44.1 dB(A) and is recommended for noise-sensitive scenarios such as the hall of a five-star hotel.

 

Clean and environment-friendly

 

A primary nylon mesh filter is preset at the air inlet.Plate filters can be added upon customer request. Multiple types of filters and sterilizers such as aluminum filter, electric purifier, and photo catalyst are available.

 

Efficient fan: 

 

An efficient forward curved fan is used. The fan features a large air flow,
low noise, and stable and reliable performance.

 

Three-grade regulation: 

 

The horizontal super-slim unit supports three-grade regulation,meeting requirements for different air flows.

 

Prevention of cold bridge: 

 

New PU materials are used for insulation, delivering excellent insulation and sound absorption performance. These materials do not absorb water, thereby effectively preventing cold bridge.

 

Prevention of condensed water: 

 

The area of the water tray in the new-generation horizontal unit increases by one time, eliminating the risks of condensed water leakage.

 

Construction party

 

Built-in unit terminal box and convenient external cable connection
Wide maintenance manhole for easy repair
Optional simple accessories such as temperature control and pressure difference alarm
Installation is easy. Flanges are set at both air inlet and outlet for easy duct connection.
The unit can be installed on floor or ceiling.

İletişim bilgileri
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

İlgili kişi: Mr. LENG Zhengliang

Tel: +86 13828797702

Faks: 86-0769-83622528

Sorgunuzu doğrudan bize gönderin (0 / 3000)

Diğer ürünler