Place of Origin: | China |
Marka adı: | EuroKlimat |
Sertifika: | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Model Number: | EKCW-D |
Minimum Order Quantity: | 5 pcs |
---|---|
Fiyat: | Negotiation |
Packaging Details: | Plywood |
Delivery Time: | 10 working days after received your payment |
Payment Terms: | T/T or L/C |
Supply Ability: | 15,000pcs per month |
Product Name: | DC Fan Coil Unit | Installation: | Ceiling hang |
---|---|---|---|
Cooling Capacity(kW): | 1.69-11.54- | Heating Capacity(kW): | 3.28-18.49 |
Air Flow(m3/s): | 279-1673 | ESP (Pa) External Static Pressure: | 0-50 |
Return Air Plenum: | Optional | Electric Heater: | Optional |
Aluminum Fins: | Shutter-type hyperbolic and hydrophilic fins | Test Pressure (Mpa): | 3.3 |
Vurgulamak: | chilled water fan coil unit,air conditioning Fan Coil Unit |
12.1 High Efficiency Low Sound Level DC Brushless Horizontal Concealed Fan Coil Unit
Specifications:(two-pipe with 2 Rows of Coils)
Model Performance |
EKCW 200ATD |
EKCW 300ATD |
EKCW 400ATD |
EKCW 500ATD |
EKCW 600ATD |
EKCW 800ATD |
EKCW 1000ATD |
EKCW 1200ATD |
||
Rated air flow (m3/h; under static pressure of 12 Pa and 30 Pa) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | |
M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | ||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | ||
Rated cooling capacity (W) | Total heating/cooling capacity | H | 1770 | 2955 | 3920 | 4635 | 5115 | 7610 | 8680 | 10495 |
Sensible heating/cooling capacity | H | 1140 | 1980 | 2570 | 3205 | 3735 | 5535 | 6680 | 7765 | |
Rated heating capacity (W) | H | 3280 | 5120 | 6450 | 7560 | 9095 | 12830 | 15865 | 18485 | |
Rated input power (W) | Static pressure of 12 Pa | H | 23 | 34 | 41 | 53 | 68 | 97 | 120 | 156 |
M | 16 | 22 | 27 | 36 | 45 | 65 | 80 | 100 | ||
L | 8 | 11 | 14 | 18 | 23 | 33 | 41 | 39 | ||
Static pressure of 30 Pa | H | 31 | 42 | 57 | 65 | 84 | 112 | 144 | 182 | |
M | 19 | 27 | 36 | 41 | 53 | 71 | 91 | 111 | ||
L | 10 | 14 | 19 | 22 | 28 | 37 | 48 | 60 | ||
Working current (A) | Static pressure of 12 Pa | H | 0.11 | 0.16 | 0.20 | 0.25 | 0.32 | 0.46 | 0.57 | 0.75 |
Static pressure of 30 Pa | H | 0.15 | 0.20 | 0.27 | 0.31 | 0.40 | 0.53 | 0.68 | 0.86 | |
Noise dB(A) | Static pressure of 12 Pa | H | 34.5 | 34.5 | 37.5 | 41.0 | 45.0 | 44.5 | 48.0 | 49.0 |
Static pressure of 30 Pa | H | 37.0 | 40.0 | 42.5 | 44.0 | 45.5 | 46.5 | 49.5 | 49.5 | |
Noise dB(A) in sleep mode | Static pressure of 12 Pa | H | 18.5 | 20.5 | 22.5 | 22.0 | 28.0 | 29.5 | 32.5 | 33.5 |
Static pressure of 30 Pa | H | 20.0 | 24.0 | 25.5 | 25.5 | 25.0 | 30.5 | 33.0 | 32.0 | |
Water flow (m3/h) | 0.32 | 0.51 | 0.67 | 0.80 | 0.88 | 1.31 | 1.47 | 1.81 | ||
Water resistance (cooling) (kPa) | 5 | 14 | 26 | 36 | 18 | 40 | 28 | 40 | ||
Water resistance (heating) (kPa) | 4 | 12 | 21 | 30 | 14 | 34 | 23 | 34 | ||
Coil | Type | Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners | ||||||||
Working pressure | 1.6MPa | |||||||||
Test pressure | Airtightness test under pressurized water: 3.3 MPa | |||||||||
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | ||||||||
Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | ||
Motor | Type | Ball-bearing brushless DC motor with a high precision and low noise | ||||||||
Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Power supply | 220V~/50Hz | |||||||||
Protection grade | IP20 | |||||||||
Insulation grade | B | |||||||||
Inlet/outlet water pipe | Pipe diameter | Rc 3/4 taper pipe with internal threads | ||||||||
Condensate water pipe | Pipe diameter | R 3/4 Taper pipe with external threads | ||||||||
Net weight | No return air plenum | kg | 10.4 | 12.3 | 14.6 | 15.4 | 16.2 | 24.4 | 27.1 | 29.4 |
With return air plenum | kg | 13.4 | 15.9 | 18.6 | 19.7 | 20.8 | 30.4 | 33.5 | 36.6 |
Notes:
■ Cooling capacity is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is
60°C, and the water flow is equal to that for cooling operation.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
■ The left/right orientation of connection pipes is exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor of 0.93 after exchange).
Specifications (two-pipe with 3 Rows of Coils)
Model Performance |
EKCW 200ACD |
EKCW 300ACD |
EKCW 400ACD |
EKCW 500ACD |
EKCW 600ACD |
EKCW 800ACD |
EKCW 1000ACD |
EKCW 1200ACD |
||
Rated air flow (m3/h; under static pressure of 12 Pa and 30 Pa) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | |
M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | ||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | ||
Rated cooling capacity (W) | Total heating/cooling capacity | H | 2260 | 3480 | 4490 | 5140 | 6450 | 8490 | 10030 | 11540 |
Sensible heating/cooling capacity | H | 1490 | 2170 | 2870 | 3600 | 4370 | 6080 | 7110 | 8500 | |
Rated heating capacity (W) | H | 3610 | 5480 | 7050 | 7900 | 9770 | 13210 | 16230 | 18160 | |
Rated input power (W) | Static pressure of 12 Pa | H | 23 | 34 | 41 | 53 | 68 | 97 | 120 | 156 |
M | 16 | 22 | 27 | 36 | 45 | 65 | 80 | 100 | ||
L | 8 | 11 | 14 | 18 | 23 | 33 | 41 | 39 | ||
Static pressure of 30 Pa | H | 31 | 42 | 57 | 65 | 84 | 112 | 144 | 182 | |
M | 19 | 27 | 36 | 41 | 53 | 71 | 91 | 111 | ||
L | 10 | 14 | 19 | 22 | 28 | 37 | 48 | 60 | ||
Working current (A) | Static pressure of 12 Pa | H | 0.11 | 0.16 | 0.20 | 0.25 | 0.32 | 0.46 | 0.57 | 0.75 |
Static pressure of 30 Pa | H | 0.15 | 0.20 | 0.27 | 0.31 | 0.40 | 0.53 | 0.68 | 0.86 | |
Noise dB(A) | Static pressure of 12 Pa | H | 34.5 | 35.0 | 36.5 | 41.5 | 44.5 | 44.5 | 47.5 | 48.5 |
Static pressure of 30 Pa | H | 37.0 | 39.0 | 42.0 | 43.0 | 46.0 | 45.5 | 50.0 | 50.0 | |
Noise dB(A) in sleep mode | Static pressure of 12 Pa | H | 25.5 | 18.0 | 20.5 | 22.0 | 27.0 | 28.5 | 32.0 | 32.5 |
Static pressure of 30 Pa | H | 22.8 | 23.0 | 24.5 | 23.5 | 26.0 | 27.5 | 33.5 | 31.5 | |
Water flow (m3/h) | 0.44 | 0.61 | 0.74 | 0.96 | 1.10 | 1.54 | 1.75 | 2.10 | ||
Water resistance (cooling) (kPa) | 13 | 30 | 17 | 24 | 36 | 36 | 29 | 40 | ||
Water resistance (heating) (kPa) | 11 | 23 | 13 | 20 | 29 | 31 | 22 | 37 | ||
Coil | Type | Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners | ||||||||
Working pressure | 1.6MPa | |||||||||
Test pressure | Airtightness test under pressurized water: 3.3 MPa | |||||||||
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | ||||||||
Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | ||
Motor | Type | Ball-bearing brushless DC motor with a high precision and low noise | ||||||||
Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Power supply | 220V~/50Hz | |||||||||
Protection grade | IP20 | |||||||||
Insulation grade | B | |||||||||
Inlet/outlet water pipe | Pipe diameter | Rc 3/4 taper pipe with internal threads | ||||||||
Condensate water pipe | Pipe diameter | R 3/4 Taper pipe with external threads | ||||||||
Net weight | No return air plenum | kg | 11.1 | 13.3 | 15.7 | 16.6 | 17.6 | 26.4 | 29.2 | 31.8 |
With return air plenum | kg | 14.1 | 16.9 | 19.7 | 20.9 | 22.2 | 32.4 | 35.6 | 39.0 |
Notes:
■ Cooling capacity is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is
60°C, and the water flow is equal to that for cooling operation.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
■ The left/right orientation of connection pipes is exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor of 0.93 after exchange).
Specifications (four-pipe with 2+1 Rows of Coils)
Model Performance |
EKCW 200AMD |
EKCW 300AMD |
EKCW 400AMD |
EKCW 500AMD |
EKCW 600AMD |
EKCW 800AMD |
EKCW 1000AMD |
EKCW 1200AMD |
||
Rated air flow (m3/h; under static pressure of 12 Pa and 30 Pa) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | |
M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | ||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | ||
Rated cooling capacity (W) | Total heating/cooling capacity | H | 1687 | 2642 | 3413 | 4105 | 4690 | 6620 | 7712 | 9350 |
Sensible heating/cooling capacity | H | 1112 | 1843 | 2496 | 3071 | 3676 | 5002 | 6162 | 7254 | |
Rated cooling capacity (W) (chilled water coil) | H | 3081 | 4505 | 5889 | 7283 | 8590 | 11437 | 14186 | 16653 | |
Rated heating capacity (W) (hot water coil) | 2360 | 3393 | 4397 | 5216 | 6182 | 7985 | 9672 | 11174 | ||
Rated heating capacity (W) (hot water coil) | 3286 | 4856 | 6279 | 7391 | 8726 | 11242 | 13640 | 15834 | ||
Rated input power (W) | Static pressure of 12 Pa | H | 23 | 34 | 41 | 53 | 68 | 97 | 120 | 156 |
M | 16 | 22 | 27 | 36 | 45 | 65 | 80 | 100 | ||
L | 8 | 11 | 14 | 18 | 23 | 33 | 41 | 39 | ||
Static pressure of 30 Pa | H | 31 | 42 | 57 | 65 | 84 | 112 | 144 | 182 | |
M | 19 | 27 | 36 | 41 | 53 | 71 | 91 | 111 | ||
L | 10 | 14 | 19 | 22 | 28 | 37 | 48 | 60 | ||
Working current (A) | Static pressure of 12 Pa | H | 0.11 | 0.16 | 0.20 | 0.25 | 0.32 | 0.46 | 0.57 | 0.75 |
Static pressure of 30 Pa | H | 0.15 | 0.20 | 0.27 | 0.31 | 0.40 | 0.53 | 0.68 | 0.86 | |
Noise dB(A) | Static pressure of 12 Pa | H | 34.5 | 35.0 | 36.5 | 41.5 | 44.5 | 44.5 | 47.5 | 48.5 |
Static pressure of 30 Pa | H | 37.0 | 39.0 | 42.0 | 43.0 | 46.0 | 45.5 | 50.0 | 50.0 | |
Noise dB(A) in sleep mode | Static pressure of 12 Pa | H | 25.5 | 18.0 | 20.5 | 22.0 | 27.0 | 28.5 | 32.0 | 32.5 |
Static pressure of 30 Pa | H | 22.8 | 23.0 | 24.5 | 23.5 | 26.0 | 27.5 | 33.5 | 31.5 | |
Chilled water coil |
Water flow (m3/h) | 1.33 | 1.50 | 1.63 | 1.75 | 1.85 | 2.18 | 2.36 | 2.67 | |
Water resistance (cooling) (kPa) | 5 | 12 | 19 | 29 | 14 | 31 | 22 | 36 | ||
Water resistance (heating) (kPa) | 4 | 10 | 16 | 24 | 11 | 26 | 18 | 29 | ||
Hot water coil | Water flow (m3/h) | 0.21 | 0.30 | 0.39 | 0.46 | 0.55 | 0.71 | 0.85 | 0.98 | |
Water resistance (heating) (kPa) | 7 | 14 | 25 | 35 | 52 | 17 | 26 | 37 | ||
Water flow (m3/h) | 0.13 | 0.20 | 0.25 | 0.30 | 0.36 | 0.46 | 0.55 | 0.64 | ||
Water resistance (heating) (kPa) | 3 | 7 | 11 | 16 | 23 | 8 | 11 | 17 | ||
Coil | Type | Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners | ||||||||
Working pressure | 1.6MPa | |||||||||
Test pressure | Airtightness test under pressurized water: 3.3 MPa | |||||||||
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | ||||||||
Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | ||
Motor | Type | Ball-bearing brushless DC motor with a high precision and low noise | ||||||||
Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Power supply | 220V~/50Hz | |||||||||
Protection grade | IP20 | |||||||||
Insulation grade | B | |||||||||
Inlet/outlet water pipe | Pipe diameter | Rc 3/4 taper pipe with internal threads | ||||||||
Condensate water pipe | Pipe diameter | R 3/4 Taper pipe with external threads | ||||||||
Net weight | No return air plenum | kg | 11.1 | 13.3 | 15.7 | 16.6 | 17.6 | 26.4 | 29.2 | 31.8 |
With return air plenum | kg | 14.1 | 16.9 | 19.7 | 20.9 | 22.2 | 32.4 | 35.6 | 39.0 |
Notes:
■ Cooling capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the water flow is equal to that for cooling operation.
■ Heating capacity (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the temperature of outlet water is 50°C.
■ Heating capacity (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 82.2°C, and the temperature of outlet water is 60°C.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
Specifications (four-pipe with 3+1 Rows of Coils)
Model Performance |
EKCW 200AHD |
EKCW 300AHD |
EKCW 400AHD |
EKCW 500AHD |
EKCW 600AHD |
EKCW 800AHD |
EKCW 1000AHD |
EKCW 1200AHD |
||
Rated air flow (m3/h; under static pressure of 12 Pa and 30 Pa) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | |
M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | ||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | ||
Rated cooling capacity (W) | Total heating/cooling capacity | H | 2530 | 3310 | 4240 | 5000 | 5890 | 8040 | 9290 | 11820 |
Sensible heating/cooling capacity | H | 1490 | 2100 | 2850 | 3350 | 4040 | 5520 | 6730 | 8300 | |
Rated cooling capacity (W) (chilled water coil) | H | 4180 | 5300 | 7030 | 7920 | 9890 | 13120 | 16120 | 20150 | |
Rated heating capacity (W) (hot water coil) | 2450 | 3170 | 4090 | 4470 | 5690 | 7290 | 8790 | 11610 | ||
Rated heating capacity (W) (hot water coil) | 3330 | 4240 | 5800 | 6670 | 7970 | 10200 | 12270 | 16420 | ||
Rated input power (W) | Static pressure of 12 Pa | H | 23 | 34 | 41 | 53 | 68 | 97 | 120 | 156 |
M | 16 | 22 | 27 | 36 | 45 | 65 | 80 | 100 | ||
L | 8 | 11 | 14 | 18 | 23 | 33 | 41 | 39 | ||
Static pressure of 30 Pa | H | 31 | 42 | 57 | 65 | 84 | 112 | 144 | 182 | |
M | 19 | 27 | 36 | 41 | 53 | 71 | 91 | 111 | ||
L | 10 | 14 | 19 | 22 | 28 | 37 | 48 | 60 | ||
Working current (A) | Static pressure of 12 Pa | H | 0.11 | 0.16 | 0.20 | 0.25 | 0.32 | 0.46 | 0.57 | 0.75 |
Static pressure of 30 Pa | H | 0.15 | 0.20 | 0.27 | 0.31 | 0.40 | 0.53 | 0.68 | 0.86 | |
Noise dB(A) | Static pressure of 12 Pa | H | 33.5 | 32.5 | 38.5 | 41.5 | 44.5 | 45.0 | 48.0 | 49.0 |
Static pressure of 30 Pa | H | 39.5 | 40.0 | 43.0 | 44.0 | 46.0 | 46.0 | 50.5 | 50.5 | |
Noise dB(A) in sleep mode | Static pressure of 12 Pa | H | 18.9 | 19.0 | 23.1 | 21.5 | 29.1 | 30.7 | 32.0 | 32.8 |
Static pressure of 30 Pa | H | 20.9 | 23.3 | 26.8 | 25.0 | 28.3 | 30.4 | 35.9 | 33.8 | |
Chilled water coil |
Water flow (m3/h) | 0.44 | 0.57 | 0.73 | 0.88 | 1.03 | 1.41 | 1.62 | 2.04 | |
Water resistance (cooling) (kPa) | 14 | 29 | 17 | 24 | 33 | 34 | 26 | 44 | ||
Water resistance (heating) (kPa) | 11 | 21 | 13 | 21 | 26 | 27 | 21 | 36 | ||
Hot water coil | Water flow (m3/h) | 0.21 | 0.27 | 0.35 | 0.38 | 0.49 | 0.63 | 0.75 | 0.97 | |
Water resistance (heating) (kPa) | 7 | 14 | 22 | 28 | 54 | 15 | 21 | 40 | ||
Water flow (m3/h) | 0.13 | 0.17 | 0.23 | 0.26 | 0.31 | 0.40 | 0.48 | 0.63 | ||
Water resistance (heating) (kPa) | 3 | 6 | 10 | 14 | 20 | 7 | 10 | 18 | ||
Coil | Type | Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners | ||||||||
Working pressure | 1.6MPa | |||||||||
Test pressure | Airtightness test under pressurized water: 3.3 MPa | |||||||||
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | ||||||||
Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | ||
Motor | Type | Ball-bearing brushless DC motor with a high precision and low noise | ||||||||
Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Power supply | 220V~/50Hz | |||||||||
Protection grade | IP20 | |||||||||
Insulation grade | B | |||||||||
Inlet/outlet water pipe | Pipe diameter | Rc 3/4 taper pipe with internal threads | ||||||||
Condensate water pipe | Pipe diameter | R 3/4 Taper pipe with external threads | ||||||||
Net weight | No return air plenum | kg | 11.8 | 14.3 | 16.8 | 17.9 | 19.1 | 28.4 | 31.4 | 34.3 |
With return air plenum | kg | 14.8 | 17.9 | 20.8 | 22.2 | 23.7 | 34.4 | 37.8 | 41.5 |
Notes:
■ Cooling capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the water flow is equal to that for cooling operation.
■ Heating capacity (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the temperature of outlet water is 50°C.
■ Heating capacity (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 82.2°C, and the temperature of outlet water is 60°C.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
Description:
EKCW Series Brushless DC Fan Coils
EKCW series brushless DC fan coils use the latest patented brushless DC technologies developed jointly by EUROKLIMAT (EK) and China Aerospace Science & Industry Corp (CASIC) and the leading-edge air processing technologies to implement stepless speed regulation. These fan coils can automatically regulate the rotation speed of motors based on the indoor load variation to maximize energy saving (saving energy by more than 65% compared with common fan coil systems). More than 300 models in the full series of units are available for customers.
Features
Efficient and Energy Saving
The unit is designed and manufactured to work withEK's efficient heat exchangers. Compared with the fan coil of a traditional AC motor, the unit saves energy by more than 65% as a whole, reducing the energy consumption for the entire HVAC system by 14%–18%.
Taking EKCW400AC1 as an example:
High speed:
Traditional fan coil - 64.0 W
Brushless DC fan coil - 46.2 W
Medium speed:
Traditional fan coil - 56.9W
Brushless DC fan coil - 20.9W
Low speed:
Traditional fan coil - 46.1W
Brushless DC fan coil - 8.4W
Item |
High speed |
Medium speed |
Low speed |
Traditional fan coil |
64.0W |
56.9W |
46.1W |
EK's brushless DC fan coil |
46.2 W |
20.9 W |
8.4 W |
Energy Saving |
27.8% |
63.3% |
81.8% |
Test Results |
The unit saves energy by 20%–35% at the nominal high speed, by 45%–65% at the nominal medium speed, and by 65%–85% at the nominal low speed. |
Generally, a fan coil reaches the set temperature within one hour after power-on, and then runs at a low or medium speed.
Objective calculation shows that EKCW series brushless DC fan coils save energy by 65% compared with traditional fan coils.
Fast Cooling/Heating
Due to a major difference between the indoor temperature and the set temperature in the initial phase of power-on, the powerful cooling/heating function of the unit can regulate the indoor temperature to the set one within a short period and control the air flow based on the actual load of the room, saving energy and generating less noise.
Due to a low temperature control precision (±2°C), traditional fan coils usually require a set temperature of 20°C–22°C to prevent unpredictable temperature changes in hot summer. Due to a high temperature control precision ((±0.5°C), EKCW brushless DC fan coils allow a set temperature of 26°C (comfortable temperature).
Constant Temperature and Comfort
EKCW brushless DC fan coils can perform proportion integration (PI) calculation based on the variation between the indoor temperature and the set temperature. These fan coils can intelligently adjust the rotation speed and air supply volume of motors within a wide range, and provide a temperature control precision of ±0.5°C, creating real and comfortable indoor environment with constant temperature.
EKCW brushless DC fan coils feature the unique sleep mode, in which the lowest noise level is only 18 dB(A), creating comfortable indoor environment with constant temperature for customers and providing a fresh and comfortable 3-D sleep space.
Strong Dehumidification
Traditional fan coils support the following operation modes: cooling, heating,and air supply (high/medium/low). EKCW series brushless DC fan coils support the following operation modes: cooling, heating, dehumidification, air supply, auto control, sleep, strong
cooling, strong heating, strong dehumidification, timing setting, fire alarm, automatic temperature control in standby mode, 2-way/3-way valve protection, and network-based control (RS485).
Optional accessories: PTC electric heater, UV+photocatalyst for sterilization, condensate water lifting pump, and anti-blocking float switch.
Adjustable Static Pressure
Traditional fan coils adapt to only one outlet static pressure. If the on-site static pressure is improper, the motor must be replaced. EKCW series brushless DC fan coils can adapt to the outlet static pressure of 0–50 Pa. The outlet static pressure can be directly adjusted on site based on temperature controller settings without replacing the motor.
Smooth Operation and Low Noise
The unit uses a forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates, featuring low noise, high wind speed, and smooth operation, and achieving the best result of air supply.
High Quality and Reliability
All coils use shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners. All coils are subject to leakage-free test under a pressure of 3.3 MPa, and are strictly inspected before they leave the factory, ensuring high performance and reliability.
No Condensation
The unit uses a condensate water collector that is molded as a whole, and features enhanced heat preservationfor the water collector and innovative batter drainage structure, effectively eliminating generation and dripping of condensation.
Even Air Supply
The unit features a rational air flow design for air supply and return so that air is evenly supplied to all corners of the room, making the room feel comfortable.
Efficient Sterilization
The unit uses sterilization technologies of nano-TiO2 photocatalyst to achieve a sterilization rate of 95%, considerably improving the air quality for work and life.
Flexible Application
The unit features the single-area controlled design, and therefore can match the master unit of any central air conditioning systems with centralized cooling/heating.
Easy Installation
With a compact, graceful, and robust design, the super-thin (only 230 mm thick) unit can be easily installed.
Leading-edge Control Technologies
The unit uses industry-leading water system control technologies and temperature control technologies to save energy during system operation.
No Electromagnetic Interference
The unit does not generate high-frequency harmonic and electromagnetic interference during stepless regulation.Therefore, the unit can be widely used in places with strict anti-interference requirements for power supply, including computer rooms, telecom base stations, TV and broadcast receiving stations, and communication equipment rooms.
Applications:
Office, Hotel , Hospital ,Supermarket ,Airport , Factory ,Villa .
Competitive Advantage:
Super Energy Saving Saves energy by more than 65%
Constant Temperature and Comfort The precision of silent temperature control reaches ±0.5°C.
Fast Cooling/Heating The speed increases by 30%.
EK Patents CASIC and EK's patents
Strong Dehumidification Outstanding dehumidifying results
Adjustable Static Pressure Adjustable static pressure of 0–50 Pa
İlgili kişi: Mr. LENG Zhengliang
Tel: +86 13828797702
Faks: 86-0769-83622528